Brochure Isolation Valves
Effective well control with unsurpassed reliability and interventionless actuation.
Trigger Mechanisms | ||||
---|---|---|---|---|
|
Interventionless | |||
|
Mechanical | N2 | S | Control Line |
FORTRESS premium isolation valve |
Y | Y | Y | |
FIV-II formation isolation valve |
Y | Y | ||
MFIV-II ꦐ mechanically controlled isolation valve |
Y | |||
AFIV 𒁃 annulus-controlled shrouded isolation valve |
Y | Y | ||
SFIV-II 🌜 surface-controlled bidirectional isolation valve |
Y | |||
TIVF flapper-seal tubing isolation valve |
Y | Y |
Completion Types | FIV-II Valve | FORTRESS Valve | MFIV-II Valve | SFIV-II Valve | AFIV Valve |
---|---|---|---|---|---|
Completion Types Intelligent completions | FIV-II • | FORTRESS • | MFIV-II • | SFIV-II • | AFIV • |
Completion Types Stand-alone screens | FIV-II • | FORTRESS • | MFIV-II • | SFIV-II • | AFIV |
Completion Types Gravel pack or frac pack | FIV-II • | FORTRESS • | MFIV-II • | SFIV-II | AFIV |
Completion Types Multizone gravel pack or frac pack | FIV-II • | FORTRESS • | MFIV-II • | SFIV-II | AFIV |
Completion Types Well suspension | FIV-II • | FORTRESS • | MFIV-II • | SFIV-II • | AFIV • |
Completion Types Lubrication | FIV-II • | FORTRESS • | MFIV-II • | SFIV-II • | AFIV |
Completion Types ESP workovers | FIV-II | FORTRESS • | MFIV-II • | SFIV-II • | AFIV |
Completion Types Underbalanced perforating | FIV-II • | FORTRESS • | MFIV-II • | SFIV-II • | AFIV |
Completion Types Multilaterals | FIV-II • | FORTRESS • | MFIV-II • | SFIV-II | AFIV |
Validation Grade | Test Medium | Flow Rate At | ||
---|---|---|---|---|
Validation Grade |
Test Medium |
Flow Rate At 200 psi Across Barrier | Flow Rate At 50% Rating | Flow Rate At 100% Rating |
Validation Grade V1 | Test Medium Liquid | Flow Rate At 10 mL/min | Flow Rate At 5 mL/min | Flow Rate At 5 mL/min |
Validation Grade V1 | Test Medium Gas | Flow Rate At 1 ft3/min | Flow Rate At 0.5 ft3/min | Flow Rate At 0.5 ft3/min |
Validation Grade V2 | Test Medium Liquid | Flow Rate At 30 mL/min | Flow Rate At 15 mL/min | Flow Rate At 15 mL/min |
Validation Grade V2 | Test Medium Gas | Flow Rate At, Flow Rate At, Flow Rate At No requirement | ||
Validation Grade V3 | Test Medium, Flow Rate At, Flow Rate At, Flow Rate At Supplier- or manufacturer-defined and successful field history of 20 similar valves |
Barrier from Above | Barrier from Below | Barrier from Above and Below | |
---|---|---|---|
Preproduction and preinjection barrier valves | Barrier from Above Type A | Barrier from Below Type B | Barrier from Above and Below Type C |
Postproduction and postinjection barrier valves | Barrier from Above Type AA | Barrier from Below Type BB | Barrier from Above and Below Type CC |